Rack Mounting
Table 3-1 Contents of 2G4072-52
Item
Matrix N Standalone Series
Accessory Kit including: power cord,
Installation Guide
Release Notes
4.Inspect the Enterasys Matrix N SA 2G4072‐52 for any signs of physical damage. Contact Enterasys Networks if it is damaged. Refer to “Getting Help” on page xviii for details.
Rack Mounting
The installation site must be within reach of the network cabling and meet the requirements listed below:
•Appropriate grounded power receptacles must be located within 7 feet of the site.
•A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation site with fluctuations of less than 10°C (18°F) per hour.
Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the device.
Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y a la parte posterior del aparato.
Warning: Before
Advertencia. Antes de montar el equipo en el rack, asegurarse que el rack puede soportar su peso sin comprometer su propia estabilidad, de otra forma, daño personal o del equipo puede ocurrir.
Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.
The Enterasys Matrix N SA 2G4072‐52 can be mounted in a standard 19‐inch rack with the two ears provided in the carton. The procedure is as follows:
1.With four of the supplied M4 x 6 mm flathead screws, attach an ear to the side of the Enterasys Matrix N SA 2G4072‐52 as shown in Figure 3‐1. Repeat the procedure for the other ear.