Rack Mounting

Table 3-1 Contents of 2G4072-52

Item

Matrix N Standalone Series 2G4072-52

Accessory Kit including: power cord, rack-mount ears, eight M4 x 6 mm flathead screws, DB9 to RJ45 converter, and adhesive feet

Installation Guide

Release Notes

4.Inspect the Enterasys Matrix N SA 2G4072‐52 for any signs of physical damage. Contact Enterasys Networks if it is damaged. Refer to “Getting Help” on page xviii for details.

Rack Mounting

The installation site must be within reach of the network cabling and meet the requirements listed below:

Appropriate grounded power receptacles must be located within 7 feet of the site.

A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation site with fluctuations of less than 10°C (18°F) per hour.

Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the device.

Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y a la parte posterior del aparato.

Warning: Before rack-mounting the device, ensure that the rack can support it without compromising stability. Otherwise, personal injury and/or equipment damage may result.

Advertencia. Antes de montar el equipo en el rack, asegurarse que el rack puede soportar su peso sin comprometer su propia estabilidad, de otra forma, daño personal o del equipo puede ocurrir.

Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.

The Enterasys Matrix N SA 2G4072‐52 can be mounted in a standard 19‐inch rack with the two ears provided in the carton. The procedure is as follows:

1.With four of the supplied M4 x 6 mm flathead screws, attach an ear to the side of the Enterasys Matrix N SA 2G4072‐52 as shown in Figure 3‐1. Repeat the procedure for the other ear.

3-2 Installation

Page 28
Image 28