EverFocus EPTZ 100 manual Appendix B Basic Settings AT Everfocus DVR, Ecor / Paragon Series

Models: EPTZ 100

1 48
Download 48 pages 35.75 Kb
Page 46
Image 46

7 APPENDIX B: BASIC SETTINGS AT EVERFOCUS DVR

The following settings are required to establish RS-485 communication between DVR and speed dome:

7.1EDR / EDVR / EDSR SERIES (EXCEPT EDSR100, EDSR100H)

1.CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel.

2.CONTROL menu: under "RS485" :

BAUD RATE:

set value identical to camera baud rate

PARITY:

NONE

DATA BIT:

8

STOP BIT:

1

PROTOCOL:

set protocol identical to speed dome protocol

NOTE: The RS-485 ID in CONTROL menu is not related to speed dome control. This RS-485 ID is used for controlling DVR by external keyboard only.

7.2ECOR / PARAGON SERIES

1.CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel.

2.SYSTEM > I/O CONTROL menu:

BAUD RATE:

set value identical to camera baud rate

PARITY:

NONE

DATA BIT:

8

STOP BIT:

1

PROTOCOL:

set protocol identical to speed dome protocol

NOTE: The RS-485 ID in menu I/O CONTROL menu is not related to speed dome control. This RS-485 ID is used for controlling DVR by external keyboard only.

46

EPTZ100_ma_en_rev03.doc

Page 46
Image 46
EverFocus EPTZ 100 manual Appendix B Basic Settings AT Everfocus DVR, EDR / Edvr / Edsr Series Except EDSR100, EDSR100H