Exatron 3000B
www.exatron.com 6-6 Chapter 6 Display Dictionary
DIAGNOSTICS
You have pressed the [DIAGNOSTICS] button. Please refer to the Diagnostics Chapter 5 of this manual
for further details on using the Diagnostics Mode.
DOUBLE PART ERR
The handler has miscycled and placed two or more devices into the test site. Make sure you are using
the correct changeover kit and that it is in good working condition. Press [Clear] to flush all miscycled
devices into output 5.
If that does not solve the problem and one of the devices then jams, pause the handler by pressing the
[PAUSE] button. Remove the red thumbscrew on the plunger assembly. Lift the plunger as sembly off
the handler, and manually free the jammed device so that it slides down into output 5. Move the
remaining device up to block the sensor in the test site.
Replace the plunger. Press [Enter] then press [Clear] to flush the second device into output tube 5.
DUT/SHUT LOST
The handler has tried to sort a device, but the shuttle did not arrive at the correct output bin. Press the [0]
key to turn off the power to all motors and manually center the shuttle at the output with the flashing LED.
Press the [0] key again to restart the handler.
You may also press the [Clear] button to center the shuttle back at output 5 and flush the handler of all
devices.
EMPTY ALL TUBES
The handler has just powered up. It is detecting output tubes. There may be devices in those tubes. The
handler has a battery backed-up RAM which holds the current tube full count.
You may:
Press [Enter] to continue operation. The handler will use its RAM count data to fill the tubes.
Remove all tubes with devices in them and then press [Enter] to continue operation.
Remove all output tubes and replace them with empty ones.
CAUTION: Before pressing [Enter] verify that no tubes with devices were installed while the
handler was off. If any devices were added at that time, the handler will overfill the tube(s).
EMPTY/LOAD PART
The handler has run out of devices to test. Reload any of the octoloader's input tubes and the handler will
automatically resume operation.
END TEST
The handler has requested an End Of Test command from the PC.
[Enter] will abort the test cycle: TEST ABORTED, and sort the device to a fail bin.
[Clear] will abort the test cycle: TEST ABORTED, and flush both the device in the test site and the device
in the mark site to the flush tube, bin 5.