Exatron 3000B
www.exatron.com 7-12 Chapter 7 Preventive Maintenance
Vacuum Generator Maintenance Guidelines
Some EXATRON Changeover Kits contain a vacuum generator (a.k.a. "venturi") to create the vacuum
used in the operation of the specific kit.
Please refer to FIGURE 7-3 following this section for vacuum generator assembly mechanical details.
Please note that in some cases, the venturi assembly will not include the control valves. Please refer to
the manufacturer's data sheet, "PISCO Vacuum Switch," in Chapter 10 of this manual for additional
information.
To Order from EXATRON:
PISCO VACUUM GENERATOR ASSEMBLY WITH CONTROL VALVES, PART #VGH10F-1/4-1/4.
PISCO VACUUM GENERATOR ASSEMBLY WITHOUT CONTROL VALVES, PART #VGH10B-1/4-1/4.
REPLACEMENT AIR FILTER, PART #VGFE10.
1. Inspect the vacuum generator's air filter weekly. The filter should be clean and white. These filters
can be cleaned, however, EXATRON highly recommends replacing dirty filters with new filters instead.
How frequently you need to replace the vacuum generator filter is a function of how clean your
environment is and how clean the devices being run are.
REMEMBER: A Dirty Filter = Poor Handler Operation.