Exatron 3000B
www.exatron.com 6-8 Chapter 6 Display Dictionary
HANDLER OUT CHKPlease refer to the Diagnostics/INTERFACE CHECK: Output Port Check (Output Cover LED Check)
section in Chapter 5 of this manual for details.
HANDLER PAUSEDYou have pressed the [PAUSE] button. The handler is now in a wait loop. Nothing will occur until you
press one or more of the handler controller’s buttons.
WHILE THE HANDLER IS IN PAUSE MODE, YOU MAY MAKE THE FOLLOWING FUNCTION CHANGES IN ANY ORDER:
PLUNGE DEPTH (Plunge-to-board change kits.)
Press the [2] key. Display will read, PLUNGE = _____. (The current plunge depth setting
will be shown.)
Enter desired plunge depth changes using the controller keypad number keys. The handler
allows changes to each digit from lowest to highest in order. First enter Ones, then Tens,
then Hundreds, then Thousands. For example: to enter a plunge depth of 625, press [5],
then [2], then [6], then [0]. The display will read: 0625.
Press the Enter button to return to HANDLER PAUSED message.
STOP ON FAIL
Press the [3] key. Display will read, STOP ON FAIL ?
Answer Yes by pressing the [1] key.
Answer No by pressing the [2] key
Press the [Enter] button to return to HANDLER PAUSED message.
PICK INTERFACE
Press the [4] key. Display will read, PICK INTERFACE ?
Select HANDLER PORT by pressing the [1] key.
Select EXATRON SUPER by pressing the [2] key.
Select PROGRAM RS-232 by pressing the [4] key.
Select EXATRON RS-232 by pressing the [5] key.
Press the [Enter] button to return to HANDLER PAUSED message.
PICK PACKAGE
Press the [5] key. Display will read, PICK PACKAGE ?
Select RUN PLCC PLUNGE by pressing the [1] key.
Select RUN DIPS PLUNGE by pressing the [2] key.
Select RUN SOIC PLUNGE by pressing the [3] key.
Select RUN AIR PLUNGER by pressing the [4] key.
Select PLCC SWING HEAD by pressing the [5] key.
Select RUN DIPS - 2800 by pressing the [6] key.
Select RUN TYPE3 SOIC by pressing the [7] key.
Select RUN SOT by pressing the [8] key.
Press the [Enter] button to return to HANDLER PAUSED .message.