Exatron 3000B
www.exatron.com 5-14 Chapter 5 Diagnostics
;
;;
; ALL MOTOR CHECK: Shuttle Motor Check
_______________________________________________________
This diagnostic tests input port C4, output port C4, C9, located on PCB #5000-397, PAL 397-3, U7.
TO ENTER THIS CHECK:
Handler displays DIAGNOSTICS
Press the [4] key.
Handler displays ALL MOTOR CHK
Press the [1] key.
Handler displays SORT MOTOR CHK
NOTE: The handler's output cover LEDs will indicate the current location of the shuttle. The correct
pattern for an empty shuttle at each output bin is as follows:
LED 1 2 3 4 5 6 7 8
BIN
1 { } { { { { { {
2 } { } { { { { {
3 { } { } { { { {
4 { { } { } { { {
5 { { { } { } { {
6 { { { { } { } {
7 { { { { { } { }
8 { { { { { { } {
} Indicates flashing LED
{ Indicates LED turned off
Press the [1] key: "1 LEFT STEP." The Shuttle will move one tube to the left.
Press the [2] key: the handler will display the current motor settings in RAM. This display is helpful when
trying to increase the motor's speed.
Press the [3] key: "1 RIGHT STEP." The Shuttle will move one tube to the right.
Press the [4] key: "2 LEFT STEPS." The Shuttle will move two tubes to the left.
Press the [6] key: "2 RIGHT STEPS." The Shuttle will move two tubes to the right.
Press the [7] key: "JOG LEFT." The Shuttle will move one step to the left, about .006".
Press the [8] key: the shuttle will try to automatically center itself at Home bin #5.
Press the [9] key: "JOG RIGHT." The Shuttle will move one step to the right, about .006".
Press the [0] key: "MOTOR OFF." The Output Sort Motor is now off.
Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.
Press the [Enter] button to EXIT this diagnostic check.