Exatron 3000B
www.exatron.com 5-3 Chapter 5 Diagnostics
[2] key = OUTPUT CHECK, then:
[1] key = SOLENOID CHECK. The following outputs will cause the corresponding
solenoid to cycle continuously until the [Enter] key is pressed.
Corresponding Override Switch:
[1] Solenoid #1 Vacuum Valve YELLOW BUTTON
[2] Solenoid #2 Air Blast WHITE BUTTON
[3] Solenoid #3 Exit Valve ORANGE BUTTON
[4] Solenoid #4 Pickup Head Valve BLACK BUTTON
[5] Solenoid #5 N/A GREEN BUTTON
[6] Solenoid #6 N/A GREY BUTTON
[7] Solenoid #7 Stack Solenoid RED BUTTON
[8] Solenoid #8 Index Solenoid BLUE BUTTON
[9] All Solenoids ON
[0] All Solenoids OFF
To return to DIAGNOSTICS Menu.
[2] key = SOL TOGGLE CHECK, then: The following keys will cause the
corresponding solenoid to either toggle on or off. It will not continuously cycle.
Corresponding Override Switch:
[1] Solenoid #1 Vacuum Valve YELLOW BUTTON
[2] Solenoid #2 Air Blast WHITE BUTTON
[3] Solenoid #3 Exit Valve ORANGE BUTTON
[4] Solenoid #4 Pickup Head Valve BLACK BUTTON
[5] Solenoid #5 N/A GREEN BUTTON
[6] Solenoid #6 N/A GREY BUTTON
[7] Solenoid #7 Stack Solenoid RED BUTTON
[8] Solenoid #8 Index Solenoid BLUE BUTTON
[9] All Solenoids ON
[0] All Solenoids OFF
To return to DIAGNOSTICS Menu.