Exatron 3000B
www.exatron.com 6-7 Chapter 6 Display Dictionary
EXATRON RS-232
Please refer to PICK INTERFACE? message later in this section.
EXATRON SUPER
Please refer to PICK INTERFACE? message later in this section.
FAIL PROGRAM
Failed programming cycle. . .
FAIL VERIFY
Failed verify cycle. . .
FAIL CHECK
Failed illegal bit check cycle. . .
FAIL LOAD
Failed to load master device. . .
The handler is using the PROGRAM RS-232 interface. The device has failed a given cycle of the
programmer operation and will be sorted to a fail output.
When any of the four messages shown above is displayed, it will be followed by a two-digit number. The
number at the end of the message indicates the error code reported back from the programm er. Please
refer to the error code section of the programmer manufacturer's manual for error code details.
FOUND PICK UP
The handler is in the Automatic Z Plunger Top Position Adjustment routine. At this point, the plunger has
picked up the DUT and is preparing to jog up to its top position. Please refer to Diagnostics Chapter 5 for
complete details.
FULL 12345678
One or more of the numbers shown above is displayed following the word FULL. Please refer to the
Diagnostics/Tube Full Sensor Check section in Chapter 5 of this manual for details.
FULL TUBE= _ _ _ _
There will be four digits displayed following the word TUBE= _ _ _ _ .
This refers to the number of devices the handler will place into each of the handler's output tubes. The
number is adjustable up to 45 devices, which would be displayed as 0045. Make certain to not set the
count for more devices than will fit into the handler's output tubes.
Use the keypad to make your selection. The handler accepts changes to each digit from lowest to
highest, in order. First enter Ones, then Tens, then Hundreds, then Thousands.
[-] The minus key will set the count to 0000.
[Enter] Sets your selection.
[Clear] Resets to the top of the handler's FULL TUBE = 0045 loop. This will also reload the handler's
EPROM default values.