www.exatron.com 5-18 Chapter 5 Diagnostics
;
;;
; OCTO/INDEX CHECK: Input Sensor Check
_______________________________________________________
This diagnostic tests port B2, located on PCB #5000-A89, PAL A89-10.
TO ENTER THIS CHECK:
Handler displays DIAGNOSTICS
Press the [5] button.
Handler displays OCTO/INDEX CHK
Press the [3] button.
Handler displays INPUT 8 if the handler is empty, and the octoloader is at the right hand stop.
1 = Not used
2 = Not used
3 = Not used
4 = Not used
5 = OPTIONAL: Fiber optic test site sensor
6 = Top of rail sensor
7 = Octo/rail gap sensor
8 = Octoloader right hand stop limit switch
If this feature, which detects device in test site, is not functional:
1. The on/off ROM address listing may be required. Please contact the EXATRON factory for assistanc e.
2. Verify that the switch on the sensor controller, part number E3X-A11, is set with L-ON and D-ON.
3. The front panel PCB, part number 5000-A89, may require a PAL update. Please contact the
EXATRON factory for assistance.
Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.
Press the [Enter] button to EXIT this diagnostic check.