Programmer’s Guide, cont’d

Integration Scaling Matrix Switcher • Programmer’s Guide4-4

Switcher-Initiated Messages
When a local event such as power-up or a front panel operation occurs, the
switcher responds by sending a message to the host. The switcher-initiated
messages are listed in the following pages. The messages are underlined.
The switcher does not expect a response from the host; but, for example, the host
program might request a new status.

Power-up

(c) Copyright 2002, Extron Electronics, ISM 482, Vx.xx
The switcher initiates the copyright message when it is first powered on. Vxxxx is
the firmware version number.

Ties creation

Out
X
2
In
X
1
All
A front panel video and audio switching operation has occurred.
X
2
is the output
number and
X
1
is the input number.
Out
X
2
In
X
1
RGB
A front panel video-only switching operation has occurred.
X
2
is the output
number and
X
1
is the input number.
Out
X
2
In
X
1
Aud
A front panel audio-only switching operation has occurred.
X
2
is the output
number and
X
1
is the input number.

Input and output video type

X
1
Typ
X
4
A front panel input video type selection has occurred.
X
1
is the input number and
X
4
is the input video type.
X
2
Rte
X
5
X
6
A front panel output video format selection has occurred.
X
2
is the output number,
X
5
is the output resolution, and
X
6
is the output refresh rate.
X
2
Syn
X
7
A front panel output video type selection has occurred.
X
2
is the output number
and
X
7
is the output video format (RGBHV or RGBS).
X
2
Pol
X
8
A front panel output video polarity selection has occurred.
X
2
is the output number
and
X
8
is the output sync polarity.