Extron electronic MVX 128 manual Performing an absolute system reset from the rear panel

Models: MVX 128

1 90
Download 90 pages 59.72 Kb
Page 52
Image 52

Operation, cont’d

4. Press and release an input or output button to exit the Serial Port Configuration mode (figure 3-56).

Press and release an

CONTROL

I/O

input or output button.

 

 

5

ENTER PRESET VIEW ESC

RGBHV AUDIO

 

All Control LEDs return to the unlit state.

 

Each I/O LED returns to its previous state.

Figure 3-56 — Exit Serial Port Configuration mode

NThe switcher requires some time to save the new serial port settings. Wait at least 5 minutes before removing power from the switcher or the settings may be lost.

Rear Panel Operations

The rear panel has a Reset button that initiates two levels of matrix switcher resets. Press and hold the button while the switcher is running or while you apply power to the switcher for different reset levels.

Performing an absolute system reset from the rear panel

This function is identical to the front panel system reset (see Performing a system reset from the front panel on page 3-32) without requiring you to power down the switcher. This function is also identical to the Esc ZQQQ SIS command, see chapter 4, Programmer’s Guide). A system reset:

Clears all ties and presets

Clears all video and audio mutes

Sets all input audio levels to unity gain (+0 dB)

Sets all output volume levels to 100% (0 dB of attenuation)

NSystem reset does not replace any user-installed firmware.

Perform a system reset as follows:

1.

Use an Extron Tweeker to press and hold the Reset button until the rear panel

 

Reset LED blinks three times (approximately 9 seconds) (figure 3-57).

 

 

 

Reset LED blinks

 

 

 

 

three times.

Release, then

4

 

 

 

9 seconds

immediately

 

 

 

 

 

Press and hold RESET

 

 

3

press and release again. RESET

 

 

 

the Reset button.

 

RESET

 

Reset LED blinks

 

 

 

 

 

 

 

3 = Blink three times, 4

= blink four times

 

four times.

 

 

 

Figure 3-57 — System reset

 

 

2.

Release the Reset button and then immediately press and release the Reset

 

button again. The reset does not occur if the second momentary press does

 

not occur within 1 second.

 

 