Software Functional Overview
Function | Address | Register | R/W |
|
| Bit Number |
| Logic | Default | Description |
|
| ||||||
Name | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
| 0 |
|
| |||||||
|
|
|
|
|
|
|
| |||||||||||
| 6Ch | PMU_LOW_ | R/W |
|
| DATA [7:0] |
| - | - |
|
|
| ||||||
| ADR |
|
|
| These registers are available | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 6Dh | PMU_HIG_ | R/W |
|
| DATA [15:8] |
| - | - | when PMU slave mode or |
| |||||||
PMU | ADR |
|
|
| charger mode is selected. |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Access |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| For detail information, refer to | ||
6Eh | CHECK_ | R/W |
|
| DATA [7:0] |
| - | - | ||||||||||
| SUM |
|
|
| PMU slave communication | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| section in this document |
| |
| 6Fh | PMU_DATA | R/W |
|
| DATA [7:0] |
| - | - |
| ||||||||
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 70h *7 | SMB_PTCL | R/W |
| PROTOCOL[7:0] |
| - | - |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 71h *7 | SMB_STS | R/W | D | A | R |
|
| STATUS |
| - | - | For detail information, refer to | |||||
| O | L | E |
|
|
| ||||||||||||
|
|
|
| N | R | S |
| [4:0] |
|
|
|
| ACPI 1.0 specification |
| ||||
|
|
|
| E | M |
|
|
|
|
|
|
|
|
|
| [ 13.9 SMBus Host controller | ||
|
|
|
|
| ADDRESS |
| R |
|
| Interface via Embedded |
| |||||||
| 72h | SMB_ADDR | R/W |
|
| E | - | - | controller] |
|
| |||||||
|
|
| [6:0] |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
| S |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| These registers are not available | |||
| 73h | SMB_CMD | R/W |
|
| COMMAND |
| - | - | |||||||||
|
|
|
| when PMU slave mode or |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| charger mode is selected. |
| |
| 74h to | SMB_DATA | R/W |
|
|
| DATA |
| - | - |
| |||||||
|
|
|
|
|
|
|
| |||||||||||
SMBus | 93h |
|
|
|
| The PMU06 has access protect | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| 94h | SMB_BCNT | R/W | RES[7:5] |
|
| BCNT[4:0] | - | - | function for the EEPROM in the | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| battery, to cancel the protection, | ||
| 95h | SMB_ | R(/W) |
| ADDRESS[6:0] |
| R | - | - | set the access protect cancel bit. | ||||||||
| ALARM_ |
|
| E | For detail, refer to SMBus |
| ||||||||||||
|
| ADDR |
|
|
|
|
|
|
|
|
|
| S |
|
| section |
|
|
| 96h to | AMB_ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ALARM_ | R(/W) |
|
|
| DATA |
| - | - |
|
|
| ||||||
| 97h |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P |
|
| PRT =1 : | The | SMBus |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| address | |||
| 98h | SMB_CNRL | R/W |
|
| RES[7:1] |
| R |
| 0x00 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| T |
|
|
| protection | is |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cancelled. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Reserve | 99h to | Reserved | R/W |
|
| Don't care |
| - | - |
|
|
| ||||||
| 9Fh |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*7: When polling checks this register, the interval time is necessary more than 500usec.
R(/W): This is the read only register, but the written data will be able to read back till PMU updates the data periodically, or PMU detects the status change.
FIC A360 Service Manual |
|