Low Battery Indication at the Display

WARNING

The Model 35360A TRACKER Display and 35300A Detector contain no internal operator serviceable

Disassembly of either unit could result in electrical h k

Always turn the 35360A TRACKER Display's power off

prior to connecting or disconnecting the interface bl

Failure to do so may result in an electrical h k

When powering the 35360A TRACKER Display from

an AC line, always use a 3-wire grounding type line cord h

as the one supplied with the 90100 TRACKER System. In addition, only connect the 35360A TRACKER Display to

AC power outlet employing a third wire safety d

Low Battery annuciator is displayed on 35360A TRACKER Display's VFD.

Yes

Operating from

No

 

AC power source?

 

Connect 35360A TRACKER Display to an AC power source and press the POWER key.

No

Low battery

Yes

 

annuciator displayed?

 

Commence operation from AC line

power or charge batteries.

Verify voltage present at AC line receptical by connecting and powering some other device.

Yes

AC line voltage present?

No

 

 

Check AC line fuses at rear panel of 35360A TRACKER Display.

No

Fuses OK?

Replace 35360A TRACKER

Display's AC line fuses.

Refer to Section 5.3.

Yes

35360A TRACKER Display is faulty and will require repair or replacement.

Figure 4-2 Low Battery Flowchart