A.4 Commands

Sense

Additional

Additional

Description

key

sense code

sense code

 

 

 

qualifier

 

 

 

 

 

0

00

00

No-sense

 

 

 

 

2

00

00

Not ready

 

 

 

 

3

80

01

Jam

 

 

 

 

3

80

02

ADF cover open

 

 

 

 

3

80

03

Document chuter empty of paper

 

 

 

 

3

80

04

Detects job separation sheet

 

 

 

(See Appendix A.5)

 

 

 

 

4

80

01

Blown fuse for FB motor

 

 

 

 

4

80

03

Blown lamp fuse

 

 

 

 

4

80

04

Blown fuse for ADF motor

 

 

 

 

4

80

05

Mechanical alarm

 

 

 

 

4

80

06

Optical alarm

 

 

 

 

4

44

00

Abnormal internal target

 

 

 

 

4

47

00

SCSI parity error

 

 

 

 

5

00

00

Page end is detected before reading

 

 

 

(VGATE ON) when page end detection

 

 

 

is enabled.

 

 

 

 

5

1A

00

Parameter length illegal

 

 

 

 

5

20

00

Invalid command

 

 

 

 

5

24

00

Invalid field in CDB

 

 

 

 

5

25

00

Unsupported logical unit

 

 

 

 

5

26

00

Invalid field in parameter list

 

 

 

 

5

2C

02

Wrong window combination

 

 

 

 

5

2C

00

Command sequence error

 

 

 

 

6

00

00

UNIT ATTENTION

 

 

 

 

B

43

00

Message error

 

 

 

 

B

45

00

SELECT/RESELECT FAILURE

 

 

 

 

B

47

00

SCSI parity error

 

 

 

 

B

80

01

Image transfer error

 

 

 

 

l.Sense-key specific bytes: Bytes F to 11 This field is reserved on this scanner.

(X’00000000’ must not be expected.)

Appendix A-45