A.4 Commands
Sense | Additional | Additional | Description |
key | sense code | sense code |
|
|
| qualifier |
|
|
|
|
|
0 | 00 | 00 | |
|
|
|
|
2 | 00 | 00 | Not ready |
|
|
|
|
3 | 80 | 01 | Jam |
|
|
|
|
3 | 80 | 02 | ADF cover open |
|
|
|
|
3 | 80 | 03 | Document chuter empty of paper |
|
|
|
|
3 | 80 | 04 | Detects job separation sheet |
|
|
| (See Appendix A.5) |
|
|
|
|
4 | 80 | 01 | Blown fuse for FB motor |
|
|
|
|
4 | 80 | 03 | Blown lamp fuse |
|
|
|
|
4 | 80 | 04 | Blown fuse for ADF motor |
|
|
|
|
4 | 80 | 05 | Mechanical alarm |
|
|
|
|
4 | 80 | 06 | Optical alarm |
|
|
|
|
4 | 44 | 00 | Abnormal internal target |
|
|
|
|
4 | 47 | 00 | SCSI parity error |
|
|
|
|
5 | 00 | 00 | Page end is detected before reading |
|
|
| (VGATE ON) when page end detection |
|
|
| is enabled. |
|
|
|
|
5 | 1A | 00 | Parameter length illegal |
|
|
|
|
5 | 20 | 00 | Invalid command |
|
|
|
|
5 | 24 | 00 | Invalid field in CDB |
|
|
|
|
5 | 25 | 00 | Unsupported logical unit |
|
|
|
|
5 | 26 | 00 | Invalid field in parameter list |
|
|
|
|
5 | 2C | 02 | Wrong window combination |
|
|
|
|
5 | 2C | 00 | Command sequence error |
|
|
|
|
6 | 00 | 00 | UNIT ATTENTION |
|
|
|
|
B | 43 | 00 | Message error |
|
|
|
|
B | 45 | 00 | SELECT/RESELECT FAILURE |
|
|
|
|
B | 47 | 00 | SCSI parity error |
|
|
|
|
B | 80 | 01 | Image transfer error |
|
|
|
|
l.
(X’00000000’ must not be expected.)
Appendix