A.4 Commands

2)Lamp timer PAGE (PAGE CODE X’3D’)

 

7

6

5

4

3

 

2

1

0

Byte 0

 

 

 

 

 

 

 

 

 

(Reserved)

 

 

 

Page code (X’3D’)

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter length (X’06’)

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

Lamp timer

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

 

 

 

(Reserved)

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP TIMER: Byte 2

The time during which the fluorescent lamp lights. 0: default (60 seconds). Up to 255 seconds can be set up in units of second.

3)Job separation sheet (PAGE CODE X’3E’)

 

7

6

5

4

3

 

2

1

0

Byte 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Reserved)

 

 

 

 

Page code (X’3E’)

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter length (X’06’)

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

 

 

 

(Reserved)

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-PARAMETER: Byte 2

X’80’: Reports check condition status when detects job separation sheet.

X’00’: Does not report check condition status when detects job separation sheet. Spec. of job separation sheet shown in A.5.

Appendix A-99