Operation and Maintenance
5.1.4Function of CE mode
CE mode is available only for maintenance person, so the details of the CE mode are shown in the maintenance manual of this scanner. In this section only the items of the CE mode is shown in
table 5.4 as a reference.
|
| Table 5.4 Function of CE mode |
|
| |
Items | Features | |
|
|
|
T01 | Single Test feed | Scanner tests the FB or ADF single sheet reading. |
|
| Scanner tests not only the feeding but also AGC control of |
|
| carrier unit and Optical unit. |
|
|
|
T02 | Multi Test feed | Scanner continuously tests the feeding and AGC control |
|
| unit “Exit” is pressed. |
|
|
|
T03 | Offset Adjsutment | Scanner automatically adjusts the offset of FB image, |
|
| ADF front image and ADF back image. |
|
|
|
T04 | EEPROM Setting | This function supports the inquiry and |
|
| EEPROM data. |
|
|
|
T05 | OP Panel Test | Scanner tests the function of the LCD, LEDs and switches |
|
| on the operator panel. |
|
|
|
T06 | ADF Sensor Test | Scanner tests the switches on ADF indicating the ON/OFF |
|
| real time status on LCD. |
|
|
|
T07 | PROM Version | Scanner displays the firmware version in PROM. |
|
|
|
T08 | Life Counter | Scanner displays the accumulated sheet number wich ADF |
|
| has fed. |
|
|
|
T09 | Baud Rate | This function supports the baud rate setting of RS232C. |
|
| Baud rate is selectable from 9600/4800/2400/1200 bps. |
|
|
|
T10 | Product ID | This function supports the setting of Product ID of SCSI |
|
| interface. |
|
| Product ID is selectable from |
|
| M3099G/M3097DG/M3097G/M3093DG/M3093GX/M30 |
|
| 96G/M3096GX. |
|
|
|
T11 | Memory Test | Scanner tests the image memory. |
|
|
|