Specifications

2.4Physical specifications

 

 

 

Table 2.5

Physical specifications

No.

 

Item

 

 

M3097DE/DG

 

 

 

 

 

 

1

Dimensions

 

Height

 

234 ( 9.2 in.)

 

(mm)

 

Width

 

696 (27.4 in.)

 

 

 

Depth

 

497 (19.6 in.)

2

Weight (Kg)

 

 

 

20 ( 44.2 lb)

3

Power

 

Voltage (VAC)

 

100 to 120, 200 to 240 VAC ±10%

 

requirements

 

Phase

 

Single

 

 

 

 

Frequency

 

50/60 Hz +2% -4%

4

Power consumption (VA)

 

120

 

5

Heat capacity

 

 

 

78 kcal ( 312 BTU/H)

6

Surge current (A)

 

 

 

30

 

7

Momentary power failure

 

100 % 0.5 Hz

8

Leakage current (mA)

 

0.75 or less

9

Dielectric strength

 

AC 1.5 KV or more for one minute or

 

 

 

 

 

more (between FG and AC lines)

10

AC line noise

 

 

 

Voltage 1.2 KV pulse duration 5 μs

11

Temperature (°C)

Operating

 

+5 to +35

 

 

 

 

Non operating

 

-20 to +60

 

12

Relative humidity

 

Operating

 

20 to 80 (No condensation)

 

(%)

 

Non operating

 

8 to 95 (No condensation)

13

Vibration (G)

 

Operating

 

0.2

 

 

 

 

Non operating

 

0.4

 

14

Indication

 

Operating

 

5

 

 

(degree)

 

Non operating

 

10

 

15

ESD (KV)

 

 

 

8 or more

 

16

Acoustic noise

 

Operating

 

53 or less

(ISO DIS 9296)

 

(dBA)

 

Non operating

 

40 or less

(ISO DIS 9296)

2.5Regulation conformity

 

Table 2.6

Regulation conformity

 

Item

Conformed regulation

 

Regulation mark on the

Remarks

 

 

 

scanner

 

 

 

 

 

 

Safety

UL 1950

 

Yes, CSA NRTL-C mark

 

 

CSA 22.2 950

 

 

 

 

 

 

 

 

 

EN60950 1992/A1:1993/A2:1993

 

Yes, GS mark by TUV

 

 

 

 

 

 

EMI

FCC Part15 Class A

 

Yes

 

etc.

 

 

 

 

EN55022 1994 Class B

 

Yes, CE mark

EMI

 

 

 

 

 

 

EN50082-1 1992

 

 

Immunity

 

 

 

 

 

 

EN61000-3-2 1995

 

 

Harmonic emission

 

 

 

 

 

 

EN61000-3-3 1995

 

 

Voltage variation

2-4