Specifications
|
|
| Table 2.5 | Physical specifications | ||
No. |
| Item |
|
| M3097DE/DG | |
|
|
|
|
|
| |
1 | Dimensions |
| Height |
| 234 ( 9.2 in.) | |
| (mm) |
| Width |
| 696 (27.4 in.) | |
|
|
| Depth |
| 497 (19.6 in.) | |
2 | Weight (Kg) |
|
|
| 20 ( 44.2 lb) | |
3 | Power |
| Voltage (VAC) |
| 100 to 120, 200 to 240 VAC ±10% | |
| requirements |
| Phase |
| Single |
|
|
|
| Frequency |
| 50/60 Hz +2% | |
4 | Power consumption (VA) |
| 120 |
| ||
5 | Heat capacity |
|
|
| 78 kcal ( 312 BTU/H) | |
6 | Surge current (A) |
|
|
| 30 |
|
7 | Momentary power failure |
| 100 % 0.5 Hz | |||
8 | Leakage current (mA) |
| 0.75 or less | |||
9 | Dielectric strength |
| AC 1.5 KV or more for one minute or | |||
|
|
|
|
| more (between FG and AC lines) | |
10 | AC line noise |
|
|
| Voltage 1.2 KV pulse duration 5 μs | |
11 | Temperature (°C) | Operating |
| +5 to +35 |
| |
|
|
| Non operating |
|
| |
12 | Relative humidity |
| Operating |
| 20 to 80 (No condensation) | |
| (%) |
| Non operating |
| 8 to 95 (No condensation) | |
13 | Vibration (G) |
| Operating |
| 0.2 |
|
|
|
| Non operating |
| 0.4 |
|
14 | Indication |
| Operating |
| 5 |
|
| (degree) |
| Non operating |
| 10 |
|
15 | ESD (KV) |
|
|
| 8 or more |
|
16 | Acoustic noise |
| Operating |
| 53 or less | (ISO DIS 9296) |
| (dBA) |
| Non operating |
| 40 or less | (ISO DIS 9296) |
| Table 2.6 | Regulation conformity |
| |
Item | Conformed regulation |
| Regulation mark on the | Remarks |
|
|
| scanner |
|
|
|
|
|
|
Safety | UL 1950 |
| Yes, CSA |
|
| CSA 22.2 950 |
|
|
|
|
|
|
|
|
| EN60950 1992/A1:1993/A2:1993 |
| Yes, GS mark by TUV |
|
|
|
|
|
|
EMI | FCC Part15 Class A |
| Yes |
|
etc. |
|
|
|
|
EN55022 1994 Class B |
| Yes, CE mark | EMI | |
|
|
|
|
|
|
|
| Immunity | |
|
|
|
|
|
|
|
| Harmonic emission | |
|
|
|
|
|
|
|
| Voltage variation |