A.4 Commands
b.Count: bytes 2 to 4
This scanner does not support this field. If a value other than 0 is specified, this scanner returns the following error information:
∙ Status: | B’00001’ (CHECK CONDITION) |
∙ Sense key: X’5’ (ILLEGAL REQUEST)
(2)Response
This scanner reports the OBJECT POSITION command as follows:
a.Normal
The GOOD status is returned.
∙ Status: B’00001’ (GOOD)
∙ Sense key: X’5’ (NO SENSE)
b.Abnormal
The CHECK CONDITION status is returned and sense data is created.
∙ Status: | B’00001’ (CHECK CONDITION) |
∙Send key: X’5’ (MEDIUM ERROR)
(The cause of the error is jammed paper, an opened ADF cover, or an empty paper supply.)
Appendix