A.4 Commands

b.Count: bytes 2 to 4

This scanner does not support this field. If a value other than 0 is specified, this scanner returns the following error information:

Status:

B’00001’ (CHECK CONDITION)

Sense key: X’5’ (ILLEGAL REQUEST)

(2)Response

This scanner reports the OBJECT POSITION command as follows:

a.Normal

The GOOD status is returned.

Status: B’00001’ (GOOD)

Sense key: X’5’ (NO SENSE)

b.Abnormal

The CHECK CONDITION status is returned and sense data is created.

Status:

B’00001’ (CHECK CONDITION)

Send key: X’5’ (MEDIUM ERROR)

(The cause of the error is jammed paper, an opened ADF cover, or an empty paper supply.)