A.4 Commands
(a)Window identifier: Byte 0
Specifies a unique value that identifies a window. The value must be 0 (00h), if the window data is
∙ Status: | B’00001’ (CHECK CONDITION) |
∙ Sense key: X’5’(ILLEGAL REQUEST)
(b)Auto: Byte 1
This scanner does not support Auto. If a value other than 0 is specified, this scanner returns the following error information:
∙ Status: | B’00001’ (CHECK CONDITION) |
∙ Sense key: X’5’ (ILLEGAL REQUEST)
(c)X, Y resolution (XR, YR) : Bytes 2 to 3 and 4 to 5
Specified here are the resolutions in the horizontal (X) and vertical (Y) scanning directions, in pixels per inch. If 0 is specified, the default value (400 dpi) is assumed.
If the image processing option is not equipped, the acceptable resolution value is as follows.
Binary reading | 0, | 600, | 400, 300, 240, 200, 150 or 100 |
|
|
|
|
Gray scale reading | 0, | 400, | 300, 240, 200, 150 or 100 |
|
|
|
|
If the option is equipped the acceptable value is in the range as follows.
Binary reading | 0 or 50 to 800 dpi with 1 dpi step |
|
|
Gray scale | 0 or 50 to 400 dpi with 1 dpi step |
reading |
|
|
|
If the values are specified that does not comply with these conditions, the scanner returns the following error information.
∙ Status: | B’00001’ (CHECK CONDITION) |
∙Sense key: X’5’ (ILLEGAL REQUEST)
The value of
(d)Upper left X, Y (ULX, ULY) : Bytes 6 to 9, A to D
Specified here are the X and Y coordinates of the
Appendix