A.4 Commands
∙Image emphasis: Byte 2B
This scanner is limited to three levels of emphasis and one level of smoothing. These levels are specified as follows:
Value (Hex) | Meaning |
|
|
00 | Without emphasis and smoothing |
|
|
01 to 2F | Low emphasis |
|
|
30 to 4F | Medium emphasis |
|
|
50 to 7F | High emphasis |
|
|
80 to FF | Smoothing |
|
|
When the
- Status: | B’00001’ (CHECK CONDITION) |
- Sense key: X’5’ (ILLEGAL REQUEST)
∙Automatic separation: byte 2C
Specifies the automatic separation for the window. When the automatic separation is performed, X’80’ is specified. When the automatic separation is not performed, X’00’ is specified. When the
- Status: | B’00001’ (CHECK CONDITION) |
- Sense key: X’5’ (ILLEGAL REQUEST)
∙Mirror image: byte 2D
Specifies the mirroring for the window. When the mirroring is performed, X’80’ is specified. When the
- | Status: | B’00001’ (CHECK CONDITION) |
- | Sense key: | X’5’ (ILLEGAL REQUEST) |
Appendix