A.4 Commands
∙PF (PAGE FORMAT): Byte 1
When PF=1, it is indicated that the parameters of this command is fitted to the
For this scanner, PF=1 only is supported.
Otherwise, the following error is returned:
- | Status: | B’00001’ (CHECK CONDITION) |
- | Sense key: | X’5’ (ILLEGAL REQUEST) |
∙SP (SAVE PAGES): Byte 1 This scanner ignores SP.
∙PARAMETER LIST LENGTH: Byte 4
Specifies the number of bytes of the mode parameter list sent in the DATA OUT phase.
0 means that there is no data to be transferred. This is not regarded as an error.
(2)Mode parameter list data: DATA OUT phase (Initiator to Target)
The mode parameter list data consists of one header, 0 or more than one descriptor block, and 0 or more than one page as one unit.
In this scanner, the descriptor block and
a.Header
The mode parameter data (header) is shown below:
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Byte 0
1
2
(Reserved)
3 | Block descriptor length |
|
|
Appendix