Appendix B Interface deference between M3097DG and M3093DG
The interface difference between M3093DG and M3093DG is explained in this appendix. Unless otherwise specified here, the interface of M3097DG is same as that of M3093DG.
B.1 Product identificationM3097DG and M3093DG return the following product identifications when requested by INQUIRY command. The product identification is specified by the bytes 10 to 1F of standard inquiry data.
Table B.1.1 Product identificationScanner type | M3097DG | M3093DG |
|
|
|
Scanner without option | M3097DGdm | M3093DGdm |
|
|
|
Scanner with | M3097DGdim | M3093DGdim |
|
| |
|
|
|
M3097DG and M3093DG can emulate following products by the following method.
Table B.1.2 Scanner which can be emulated
| M3097DG | M3093DG |
|
|
|
Scanner which can be | M3099G | M3099G |
emulated * | M3099GH | M3096G |
| ||
| M3097D | M3093GX |
| M3096GX |
|
| M3093DG |
|
|
|
|
Method of emulation | Selecting in the Setup mode of | Switching the ADF sensor and |
| the operator panel | power switch (see OEM |
|
| manual) |
|
|
|
* The suffix of the emulated product ID is same as M3093DG/M3097DG.
B.2 Window width and lengthM3097DG and M3093DG return following window width and window length in vital product data (byte 14 to 1B). These data means the width and length that can be read by the scanner in basic resolution dots.
Table B.2.1 Window width and length
|
| M3097DG |
| M3093DG |
|
|
|
|
|
Window width (Byte 14 to 17) |
| X’00001300’ |
| X’00000D80’ |
|
|
|
|
|
Window length(Byte 18 to 1B) |
| X’00001B00’ |
| X’000015E0 |
|
|
|
|
|
Ex. : X’00001300 = 4864 , | X’00001B00 = 6912 |
|
Appendix