5.1 Operator panel operation

5.1.3Setup mode

Operator can set following items by Setup mode.

Table 5.3 Functions of Setup mode

No

Item

Description

Selectable

Default

 

 

 

parameters

 

 

 

 

 

 

1

Double feed

Double feed is detected by checking

Tolerance:

No

 

check

the document length one by one.

No/10/15/20

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

2

IPC pre-setting

Scanner automatically sets the

Document:

No

 

 

recommended reading parameters.

No/1/2/3/4/5

 

 

 

Five sets of recommended

 

 

 

 

 

 

 

parameters are available.

 

 

 

 

 

 

 

3

Reset of

Abrasion counter can be reset.

-

-

 

Abrasion counter

 

 

 

 

 

 

 

 

4

Pick start time

The time from the document

Time:

 

 

setting

insertion to the start of picking is

0.2 to 9.8 sec

1.0 sec

 

 

specified. User can select most

 

 

 

 

 

 

comfortable Pick start time for the

 

 

 

 

job.

 

 

 

 

 

 

 

4

Time-out limit

The time that the scanner waits for

Time:

 

 

setting *

next document insertion after last

27 values from

30 sec

 

 

document scanned can be specified.

 

 

1 to 1999 sec

 

 

 

 

 

 

 

 

 

 

5

ADF front offset

Horizontal and vertical offset of the

Offset:

Offset:

 

setting *

front side image by ADF is

H: -2 to +3mm

H: 0 mm

 

 

specified.

 

 

 

 

 

 

 

V: -2 to +3mm

V: 0 mm

 

 

 

 

 

6

ADF back offset

Horizontal and vertical offset of the

Offset:

Offset:

 

setting *

back side image by ADF is

H: -2 to +3mm

H: 0 mm

 

 

specified.

 

 

 

 

 

 

 

V: -2 to +3mm

V: 0 mm

 

 

 

 

 

7

FB offset

Horizontal and vertical offset of the

Offset:

Offset:

 

setting*

FB image is specified.

H: -2 to +3mm

H: 0 mm

 

 

 

 

 

 

V: -2 to +3mm

V: 0 mm

 

 

 

 

 

8

IPC/Memory

The type of IPC option (IPC-2D or

 

 

 

status display

IPC-3D) and total memory installed

 

 

 

 

are displayed.

 

 

 

 

 

 

 

9

SCSI ID setting

SCSI ID is selectable

SCSI ID:

 

 

 

 

1/2/3/4/5/6/7

5

 

 

 

 

 

*This offset means the deference from the value adjusted by automatic offset adjustment.

5-3