Furuno DS-60 installation manual Transceiver Unit DS-620, Installation considerations

Models: DS-60

1 65
Download 65 pages 55.6 Kb
Page 10
Image 10

1. INSTALLATION

1.2Transceiver Unit DS-620

Installation considerations

Since the transceiver unit generates heat, install it in a dry, well-ventilated place. The cooling fans at the top of the unit must not be obstructed, to allow heat to escape.

This unit is designed for bulkhead mounting to permit dissipation of heat. If bulkhead mounting is absolutely impossible, mount the unit on the floor leaving at least 350 mm clearance between it and the floor to permit dissipation of heat.

Reinforce the mounting area, if necessary.

Leave space around the unit for maintenance and checking. Refer to the drawing at the back of this manual for minimum recommended maintenance space.

A magnetic compass will be affected if the transceiver unit is placed too close to it. Observe the compass safe distances to prevent disturbance to the magnetic compass (page i).

Use four hex. bolts (M10x20) to fix the transceiver unit to the mounting area. See the outline draw- ing at the back of this manual.

1.Screw in lower hex. bolts so there is 5 mm clearance between bottom of screw head and bulk- head.

2.Hang the unit on the bolts, then tighten the bolts.

3.Fasten the unit with upper hex. bolts.

Fixing hole 2- 12

210±1 (8.27”)

590±1 (23.23”)

15 (0.59”)

12 (0.47”) 210±1 (8.27”)

620 (24.41”)

35 (1.38”)

(7)

1-4

Page 10
Image 10
Furuno DS-60 installation manual Transceiver Unit DS-620, Installation considerations