Furuno DS-60 installation manual DS-620 Transceiver unit

Models: DS-60

1 65
Download 65 pages 55.6 Kb
Page 33
Image 33

2. WIRING

2.2Transceiver Unit DS-620

Cables TTYCY-4S, DPYCY-4 and the transducer cable are connected to the DS-620. Fabricate and pass them through their respective the cable clamps at the bottom.

DS-620 Transceiver unit

TTYCY-4S

 

80

30

7

10

 

 

 

80

 

 

Vinyl tape

×3

DPYCY-4

150

 

10

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vinyl tape

Transducer cable

400 (for TB6*)

 

20

100

50

7 20

×3

 

20

×3

×3

 

150 (for TB4*)

 

 

 

 

 

250 (for TB5*)

Wrap wires of cables connected

to TB4, TB5 and TB6 with conductive tape. Then, wrap them with vinyl tape.

TB6

1

2

3

4

5

6

 

 

 

TB5

 

 

 

1

 

 

 

2

 

 

 

3

 

 

 

4

 

 

 

5

 

 

TB2

6

 

 

 

 

 

1

TB4

 

 

2

 

 

1

 

 

3

 

 

4

2

 

 

5

3

TB1

6

4

 

 

7

5

1

2

 

6

 

 

DPYCY-4.0 TTYCY-4S Transducer cable

Conductive tape (TR-19 L=3000, supplied)

Wrap the conductive tape around cable two or three times, and set the taped part in the cable clamp.

Note: The transducer cable has nine twisted-pairs of signal lines. Be careful to con- nect them to the correct connectors in the transducer unit.