1. INSTALLATION

1.6Installation of Display Unit with DS-605 (Water Proof Box, option)

For installation of the display unit on the wings of the bridge, use the optional water proof box DS- 605. Fix the DS-605 on the bulkhead and set the display unit therein.

Installation materials for DS-605 (Type: CP66-01731, Code No.: 001-082-660-00)

Name

Type

Code No.

Qty

Remarks

 

 

 

 

 

Seal Washer

03-001-3002-0 RoHS

300-130-020-10

4

 

 

 

 

 

 

Gasket (2)

26-003-1605

100-355-310-10

1

For DS-60

 

 

 

 

 

Washer (2)

26-003-1607

100-355-320-10

2

 

 

 

 

 

 

Cable Gland Washer

JIS F8801 25C

000-172-238-10

2

For RD-50

 

 

 

 

 

Cable Grand Inner gasket

JIS F8801 25C

000-171-892-10

1

 

 

 

 

 

 

Silicon Rubber

S-8400W 50G

000-158-483-10

1

 

 

 

 

 

 

Mounting considerations

The DS-605 has waterproofing protection of IP56. When you select a mounting location for the waterproof box, keep in mind the following points.

Keep the unit away from electromagnetic field-generating equipment like motors and genera- tors.

For maintenance and checking purposes, leave enough space at the sides of the unit and leave slack in cables. See the outline drawing at the back of this manual.

A magnetic compass will be affected if the waterproof box is too close to the magnetic com- pass. Observe the compass safe distances (see page i) to prevent interference to a magnetic compass.

Mounting procedure

Note: Mount the DS-605 on the bulkhead so the cable glands and the drain hole are down.

1.Fix the DS-605 on the wings of the bridge.

1)Insert the seal washer to four fixing holes.

2)Fix the DS-605 with four M10 bolts (dockyard supply).

176 ± 0.5 62 (2.44”) (6.93”)

340 (13.39”)

310 ± 0.5 (12.20”)

Fixing hole 4-ø12

Note: Mount the unit so the cable glands are down.