Furuno DS-60 installation manual Installation

Models: DS-60

1 65
Download 65 pages 55.6 Kb
Page 19
Image 19

1. INSTALLATION

9.Pass the gasket (8), flat washer (7) and fixing gland (11) through the transducer cable.

Transducer cable

Fixing gland (11)

Washer (7)

The hollow side must be downward.

Gasket (8)

Shaft (6)

Hex. bolt (26)

Seal washer (27)

Transducer (1)

10.Fasten the fixing gland (11) to the top of the shaft (6).

The height between the top of the fixing gland (11) and the top of the shaft (6) must be less than 7 mm.

11.Apply grease (supplied) to both sides of the gasket 1 (5), and set it on the spacer (3). 12.Apply grease (supplied) to the inside of the spacer (3).

13.Clean the top and bottom of the gate valve (2), and mount it on the gasket 1 (5) mounted on the spacer (3) at step 11.

1-13

Page 19
Image 19
Furuno DS-60 installation manual Installation