Furuno DS-60 installation manual Wiring, Precautions for cable installation

Models: DS-60

1 65
Download 65 pages 55.6 Kb
Page 29
Image 29

2.WIRING

Refer to the interconnection diagram at the back of this manual to connect cables.

Distributor

DS-610Remote Controller RD-501/

Dimmer Controller RD-502

TTYCYS-4

Display Unit

(main)

DS-600

100-240 VAC (DPYC-2.5)

DS-340 (CO-SPEVV-SB-C)

ANALOG VOLTAGE OUT (TTYCS-1) ANALOG CURRENT OUT (TTYCS-1)

KP IN/OUT (TTYCS-1, x2)

ALARM SYSTEM ANALOG METER OUT (TTYCYS-1Q, x2)

DIGITAL OUT

DIGITAL OUT

LOG/CONTACT, 200 pulse (DPYCY-1.5, x4) IEC61162/IN (TTYCS-1, x3)

IEC61162/OUT (TTYCS-1, x5)

TTYCYS-4 or TTYCS-4

 

 

(Max. 150 m)

 

 

Display Unit (sub) DS-600, RD-20/50 (x5)

 

 

Transceiver Unit

Junction Box

DS-620

DS-640 (option)

 

 

TTYCY-4S*

TTYCY-4S*

 

 

DPYCY-4.0*

 

 

DPYCY-4.0*

 

 

 

Transducer cable

Transducer

(30 m/40 m/50 m/60 m)

DS-630/631

*The cable length between DS-620 and DS-610 must be less than 500 m.

Note: For details of JIS (Japan Industrial Standard) cables, see APPENDIX 2.

Precautions for cable installation

Observe the following guidelines to prevent noise, interference problem.

The transducer cable carries very weak signals (amplitude less than 0.1 μV), which are easily interfered by noise. The need for a good ground cannot be overempha- sized.

Locate DS-60 cables away from the transmission antenna cable or radio equip- ment.

Locate the DS-60 cables away from the power cables mentioned below. Also, sep- arate cables at least 400 mm when the cables are run parallel with power cables.

Cable carrying more than a few kilowatts power to fluctuating loads

Cable carrying switching waves generated by thyristor, etc.

2-1