Setting method 1: by gyrocompass specifications

1) Gyrocompass type

Gyrocompass

SW

SW

SW

JP1

type

1-4

1-5

1-6

 

 

 

 

 

 

AC synchronous

OFF

OFF

OFF

#1,

 

 

 

 

#2, #3

 

 

 

 

 

DC synchronous

OFF

OFF

OFF

#2,

 

 

 

 

#3, #4

 

 

 

 

 

DC step

ON

OFF

OFF

#4,

 

 

 

 

#5, #6

 

 

 

 

 

Full-wave

OFF

ON

OFF

#4,

pulsating current

 

 

 

#5, #6

 

 

 

 

 

Half-wave

ON

ON

OFF

#4,

pulsating current

 

 

 

#5, #6

 

 

 

 

 

2) Frequency

Frequency

SW

SW

Remarks

 

1-7

1-8

 

 

 

 

 

50/60Hz

OFF

OFF

AC synchronous

 

 

 

pulsating current

 

 

 

 

400Hz

ON

OFF

AC synchronous

 

 

 

pulsating current

 

 

 

 

500Hz

OFF

ON

AC synchronous

 

 

 

pulsating current

 

 

 

 

DC

ON

ON

DC synchronous

 

 

 

DC step

 

 

 

 

3)Rotor voltage (between R1 & R2)

Rotor voltage

SW 2-1

JP3

 

 

 

20 V to 45 VAC

ON

#2

 

 

 

30 V to 70 VAC

OFF

#2

 

 

 

40 V to 90 VAC

ON

#1

 

 

 

60 V to 135 VAC

OFF

#1

 

 

 

4)Stator voltage (between S1 and S2)

Stator voltage

SW 2-2

SW 2-3

JP2

 

 

 

 

20 V to 45 VAC, or

ON

OFF

#2

20 V to 60 VDC

 

 

 

 

 

 

 

20 V to 45 VAC, or

OFF

OFF

#2

20 V to 60 VDC

 

 

 

 

 

 

 

40 V to 90 VAC

ON

OFF

#1

 

 

 

 

60 V to 135 VAC

OFF

OFF

#1

 

 

 

 

5) Ratio

Ratio

SW1-1

SW 1-2

SW1-3

 

 

 

 

360x

OFF

OFF

OFF

 

 

 

 

180x

ON

OFF

OFF

 

 

 

 

90X

OFF

ON

OFF

 

 

 

 

36X

ON

ON

OFF

 

 

 

 

6) Supply voltage

Supply voltage

JP4

JP5

 

 

 

 

20

V to 45 VAC, or

#2

#2

20 V to 60 VDC

 

 

 

 

 

 

30

V to 135 VAC, or

#1

#1

40 V to 100 VDC

 

 

 

 

 

 

7)AD-10 format data Tx interval

Select data transmitting interval for ports 1 to 6 by jumper wires JP6 and JP7.

Note: The Tx interval is available in 25 ms or 200 ms.

25 ms is for radar; 200 ms is for all other equipment.

8) NMEA-0183

Tx interval and Output sentence

Tx

SW

SW

Output

interval

2-5

2-6

sentence

 

 

 

 

1 s

OFF

OFF

HDT+VHW

 

 

 

 

200 ms

ON

OFF

HDT

 

 

 

 

100 ms

OFF

ON

HDT

 

 

 

 

25 ms

ON

ON

HDT

 

 

 

 

9)NMEA-0183 Version no.

Version no. SW3-1

1.5OFF

2.0ON

10)NMEA-0183 Baud rate

Baud rate

SW3-2

 

 

4860bps

OFF

 

 

38400bps

ON

 

 

11)NMEA-0183 Talker

Talker

SW3-3

 

 

AG

OFF

 

 

HE

ON

 

 

4-4

Page 48
Image 48
Furuno FR-2135S manual Setting method 1 by gyrocompass specifications, Gyrocompass type