INITIAL SETTING4 menu

Keying sequence: [RADAR MENU] [0] [0] [0] [2] [0] [0] [0]

MODEL: Selects radar model.

TYPE: Selects specification of radar. Select R for R type; G for IMO type.

CTR STC CURVE: Selects level of STC affect; Low, Medium or High.

RJ-7,RJ-8: Selects which Interswitch unit to use.

SHIP'S TYPE: Select class of vessel; deep sea, fishing, long line fishing.

CABLE LENGTH: Set for "500."

FACTORY DEFAULT: Restores all menus' default settings.

OWN SHIP INFORMATION menu

Keying sequence: [RADAR MENU] [0] [0] [0] [2] [6]

SHIP'S LENGTH: Enter ship's length.

SHIP'S WIDTH: Enter ship's width.

RADAR POSN: Enter distance from both bow and port to the radar antenna location.

NAV ANT POSN: Enter distance from both bow and port to the navigation an- tenna location.

TURN RATE: Enter ship's turn rate.

SPEED RATE: Enter ship's speed rate.

3-8

Page 44
Image 44
Furuno FR-2135S manual Initial SETTING4 menu, OWN Ship Information menu