How to attach NH connector

HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE

NH connector wire

NH connector housing

1Insert NH connector wire into NH connector housing.

Shrink tubing

20mm

2Cut shrink tubing in 20 mm lengths and slip onto each wire.

Solder

 

3 Solder connector

4 Heat shrink

to signal cable.

tubing with solder-

 

ing iron.

Figure 2-6 How to attach NH connector

2.2 Scanner Unit

Fabricating multicore cable 660V-MPYCY-12/250V-MPYCY- 12 (JIS cable)

1.Shorten the multicore cable making the length from the cable gland to the cable end inside the scanner unit 450 mm. Remove the vinyl sheath of the cable by 450 mm; the armor by 440 mm.

Armor

440 mm

Conductors

450 mm

Armor

Core

Vinyl sheath

φ = 1.25 mm2

Figure 2-7 Fabrication of multicore cable 660V-MPYCY-12/250V-MPYCY-12

2. Turn off the ANT MOTOR SW on the scanner unit.

Signal cable (S03-74)

ANT MOTOR SW

Multicore cable (250V-MPYCY-12 or 660V-MPYCY-12)

Figure 2-8 Scanner unit, bow view

2-6

Page 30
Image 30
Furuno FR-2135S manual How to attach NH connector, HOW to Attach NH Connector to Signal Cable