How to attach NH connector
HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE
NH connector wire
NH connector housing
1Insert NH connector wire into NH connector housing.
Shrink tubing
20mm
2Cut shrink tubing in 20 mm lengths and slip onto each wire.
Solder |
|
3 Solder connector | 4 Heat shrink |
to signal cable. | tubing with solder- |
| ing iron. |
Figure 2-6 How to attach NH connector
2.2 Scanner Unit
Fabricating multicore cable
1.Shorten the multicore cable making the length from the cable gland to the cable end inside the scanner unit 450 mm. Remove the vinyl sheath of the cable by 450 mm; the armor by 440 mm.
Armor
440 mm
Conductors
450 mm
Armor
Core | Vinyl sheath |
φ = 1.25 mm2 |
Figure 2-7 Fabrication of multicore cable 660V-MPYCY-12/250V-MPYCY-12
2. Turn off the ANT MOTOR SW on the scanner unit.
Signal cable
ANT MOTOR SW
Multicore cable