Furuno FR-2135S manual Scanner unit assembling procedure

Models: FR-2135S

1 82
Download 82 pages 36.49 Kb
Page 12
Image 12

Scanner unit assembling

The scanner radiator and the scanner housing are shipped in separate packages. Assemble them as below. The scanner unit may be assembled before hoisting it to the mounting platform. However, do not lift the scanner unit by the radiator.

Scanner unit assembling procedure

1.Screw the guide pins (2 pcs.) in the radiator.

2.Remove the protective cap from the choke guide.

3.Grease O-ring and set it to groove of the choke guide.

4.Place the radiator on the radiator bracket. (Radiator direction is shown by the logo on the bracket. If reversely oriented the radiator cannot be set to the bracket.)

5.Loosely fix the radiator to the radiator bracket with hex bolts (M10 x 25), spring washers and flat washers.

6.Remove the guides pins and tighten hexagon bolts.

Scanner radiator

Spring washer, flat washer,

10pcs. each, M1025

Protective cap

Radiator bracket

Choke guide

O-ring

(JIS B2401-

1A-G60, 2 pcs.)

Do not remove the teflon tube from the center conductor.

Guide pin (2 pcs.)

Instruction label for scanner aperature direction

Figure 1-4 Assembling the radiator

CAUTION

Be sure to remove the guide pins.

Injury may result if the guide pins loosen and fall.

1-4

Page 12
Image 12
Furuno FR-2135S manual Scanner unit assembling procedure