WIRING

2.1 Display Unit

Fabricating the power cable DPYCY-3.5 (JIS cable)

1.Remove the vinyl sheath by 80 mm.

2.Cut off jute tape wrapped around the armor.

3.Unravel the armor to expose the cores by about 35 mm.

4.Remove insulation of cores by about 10 mm. Fix crimp-on lugs to the cores and armor.

5.Cover the armor with vinyl tape, leaving the portion which will lie inside the cable clamp untaped.

(a)

Vinyl sheath

(b)

(c)

DPYCY-3.5

About

80 mm

40 mm

5 mm

Armor 10 mm

Lay this part in cable clamp.

(d)

Taping

 

 

Armor

Core

2

Vinyl

S = 3.5 mm

 

sheath

= 2.4 mm

 

DPYCY-3.5 sectional view

Figure 2-1 Fabrication of power cable DPYCY-3.5 (JIS cable)