3.Open the left side cover on the scanner unit with the hex wrench (supplied).

4.Unfasten the cable gland for the multicore cable and remove the gasket and flat washers.

5.As shown in Figure 2-9, slide the clamping gland, flat washers and gasket on the multicore cable.

6.Fold back armor by 5 mm and pass it through the two flat washers as shown in Figure 2-9.

Gasket

Armor (folded back)

 

Seal with putty after tightening.

Vinyl sheath

Clamping gland

Flat

 

 

Cable gland

washer

 

 

Flat

 

 

 

 

Flat

 

 

 

 

 

 

washer

 

washer

 

 

 

Figure 2-9 Passing clamping gland, washers and gasket on the multicore cable

7. Shorten conductors considering their locations on the terminal board STB-1.

STB-1

RTB-801

Figure 2-10 Scanner unit, port side view

8. Confirm that armor is grounded between two flat washers.

2-7