Section 6.1

Major Disassembly

Part 6

Disassembly

Figure 27.

6.Remove Left-side enclosure: Using a 10mm ratchet wrench remove the horizontal 10mm bolt that connects the side panel to the back panel. Using a 10mm socket, remove three bolts from the base of the enclosure. See Figure 28. Using a 10mm socket and wrench remove the top hinge bolt and loosen the bottom bolt. See Figure 29. Holding the roof, remove the bottom hinge bolt, remove the side panel by sliding it forward then re- install the hinge bolt.

Figure 28.

Figure 29.

7.Remove Fan Housing Cover: Using a 10mm socket remove four bolts from the fan housing cover. Remove the fan housing cover. See Figure 30.

Figure 30.

8.Remove Rotor Bolt: Using a 9/16” socket, remove rotor bolt. Figure 31.

Page 158

Page 160
Image 160
Generac Power Systems 10 kW LP, 13 kW NG, 7 kW NG, 9 kW NG, 8 kW LP, 17 kW LP, 20 kW LP, 16 kW NG, 14 kW LP, 18 kW NG manual Section