12.Remove Brush Wires: Using a side cutters remove the tie wraps securing the brush wires to the outside of sta- tor. See Figure 35.

Figure 35.

13.Remove Controls Cover: Using a Torx T-27 socket remove two bolts and ground washer from the controls cover. Remove the controls cover. See Figure 36.

Figure 36.

14.Remove Stator Wires: Remove all wires from the voltage regulator, remove the common and ground wires from landing lugs, and remove N1 & N2 wires from main bea- kers. See Figure 37.

Figure 37.

15.Alternator Air Intake Bellows Removal: Remove alterna- tor intake bellows. See Figure 38.

Figure 38.

16.Rear Bearing Carrier Removal: Using a 13mm socket, remove the two nuts from the alternator mounting brack- et rubber mounts. Lift the back end of the alternator up and place a 2”x 4” piece of wood under the engine. See Figure 40. Using a 13mm socket, remove the four stator hold down bolts. See Figure 41. Using a small rubber mallet remove the rear bearing carrier. See Figure 42. Remove stator. See Figure 43.