Repair / Réparation / Reparación

 

 

 

 

WHAT TO CHECK

WHAT TO DO

TYPE OF PROBLEM

If check is OK, go to next check

When check is not OK, refer to this column

 

 

 

 

 

 

Sprayer does not run at all

Control is commanding motor to run

6. Perform Field Short Test: Test at large 4-pin motor

 

but motor shaft does not rotate.

field connector. There should not be continuity from

Digital display shows E=05

Possibly locked rotor condition,

pin 4, the ground wire, and any of the remaining

 

 

an open connection exists between

3 pins. If motor field connector tests positive,

 

motor and control, there is a problem

replace control board.

 

with motor or control board, or

7. Check Motor Thermal Switch: Unplug thermal

 

motor amp draw is excessive.

 

 

wires. Set meter to ohms. Meter should read the

Control board status light blinks

 

With prime valve open and pressure

proper resistance for each model (see table below).

5 times repeatedly

relieved, start and stop motor

 

 

 

 

15 times using set point

 

 

potentiometer (pressure switch). If

 

 

motor restarts each time at no load,

 

 

motor is bad and must be replaced.

 

 

If motor will not restart every time,

 

 

board is at fault. Replace circuit

 

 

board.

-

ti13140a

Resistance Table:

Ironman 300E

8.2k ohms

 

 

695

0 ohms

 

 

795

2k ohms

 

 

1095

3.9k ohms

 

 

1595

6.2k ohms

 

 

313314B

37

Page 37
Image 37
Graco Inc 300E, 313314B important safety instructions Check Motor Thermal Switch Unplug thermal, Resistance Table