Control Board (With GFI Filter Coil)

Follow the steps below:

1.Plug cord in and turn switch ON. Connect wires to control board and ON/OFF switch. Meter on AC Volts.

110-120 AC

V

-

Black to board

Black from power cord

White from power cord

ti13138a

2.Plug cord in and turn switch ON. Connect wires to control board and ON/OFF switch. Meter on AC Volts.

110-120 AC

V

-

Black to board

Black from power cord

White from power cord

ti13139a

Repair / Réparation / Reparación

3.Check motor thermal switch. Unplug thermal wires (see table below for proper reading).

NOTE: Motor should be cooled down.

ti13140a

-

Resistance Table:

 

 

Ironman 300E

8.2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

695

 

0 ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

795

 

2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1095

 

3.9k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1595

 

6.2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Plug cord in and turn switch ON. Disconnect potentiometer and carefully create a short between potentiometer terminals.

Control Board

ti13141a

Refer to Wiring Diagram, page 85, for more details.