Graco Inc 300E, 313314B important safety instructions Control Board With GFI Filter Coil

Models: 313314B

1 90
Download 90 pages 39.76 Kb
Page 41
Image 41
Control Board (With GFI Filter Coil)

Control Board (With GFI Filter Coil)

Follow the steps below:

1.Plug cord in and turn switch ON. Connect wires to control board and ON/OFF switch. Meter on AC Volts.

110-120 AC

V

-

Black to board Manual backgroundManual background

Black from power cord Manual background

White from power cord

ti13138a

2.Plug cord in and turn switch ON. Connect wires to control board and ON/OFF switch. Meter on AC Volts.

110-120 AC

V

-

Black to board Manual backgroundManual background

Black from power cord Manual background

White from power cord

ti13139a

Repair / Réparation / Reparación

3.Check motor thermal switch. Unplug thermal wires (see table below for proper reading).

NOTE: Motor should be cooled down.

ti13140a

-

Resistance Table:

 

 

Ironman 300E

8.2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

695

 

0 ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

795

 

2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1095

 

3.9k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1595

 

6.2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Plug cord in and turn switch ON. Disconnect potentiometer and carefully create a short between potentiometer terminals.

Control Board

ti13141a

Refer to Wiring Diagram, page 85, for more details.

313314B

41

Page 41
Image 41
Graco Inc 300E, 313314B important safety instructions Control Board With GFI Filter Coil