WHAT TO CHECK

 

WHAT TO DO

TYPE OF PROBLEM

If check is OK, go to next check

 

When check is not OK, refer to this column

 

 

 

 

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Set sprayer to OFF and disconnect power to sprayer.

 

connections (control board is not

 

 

Digital display shows E=03

2.

Check transducer and connections to control board.

detecting a pressure signal).

 

 

 

3.

Disconnect transducer from control board socket.

 

 

 

Check to see if transducer and control board

 

 

 

contacts are clean and secure.

 

 

 

 

Control board status light blinks

 

4.

Reconnect transducer to control board socket.

3 times repeatedly

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

 

 

 

to 1/2 turn clockwise. If sprayer does not run,

 

 

 

set sprayer to OFF and go to next step.

 

 

5.

Connect a confirmed working transducer to control

 

 

 

board socket.

 

 

6.

Set sprayer ON and control knob to 1/2 turn

 

 

 

clockwise. If sprayer runs, install new transducer.

 

 

 

Replace control board if sprayer does not run.

 

 

7.

Check transducer resistance with ohmmeter (less

 

 

 

than 9k ohm between red and black wires and 3-6k

 

 

 

ohm between green and yellow wires).

 

 

 

 

313314B

35

Page 35
Image 35
Graco Inc 300E, 313314B Sprayer does not run at all Check transducer or transducer, Detecting a pressure signal