Check Motor Thermal Switch: Unplug thermal

Repair / Réparation / Reparación

 

WHAT TO CHECK

 

WHAT TO DO

TYPE OF PROBLEM

If check is OK, go to next check

 

When check is not OK, refer to this column

 

 

 

 

 

 

Sprayer does not run at all

Allow sprayer to cool. If sprayer runs

NOTE: Motor must be cooled down for the test.

 

when cool, correct cause of

 

 

Digital display shows E=06

 

 

overheating. Keep sprayer in cooler

1.

Check thermal device connector (yellow wires)

 

 

location with good ventilation. Make

 

at control board.

 

sure motor air intake is not blocked.

2.

Disconnect thermal device connector from control

 

If sprayer still does not run, follow

 

Step 1.

 

board socket. Make sure contacts are clean and

Control board status light blinks

 

 

secure.

6 times repeatedly

 

3.

Measure resistance of the thermal device. If reading

 

 

 

 

 

is not correct, replace motor.

 

 

 

Check Motor Thermal Switch: Unplug thermal

 

 

 

wires. Set meter to ohms. Meter should read the

 

 

 

proper resistance for each model (see table below).

 

 

4.

Quick test for Ultras

-

ti13140a

 

 

 

 

Resistance Table:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ironman 300E

8.2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

695

0 ohms

 

 

 

 

 

 

 

 

 

 

 

 

795

2k ohms

 

 

 

 

 

 

 

 

 

 

 

 

1095

3.9k ohms

 

 

 

 

 

 

 

 

 

 

 

 

1595

6.2k ohms

 

 

 

 

 

 

 

 

 

 

5.

Reconnect thermal device connector to control

 

 

 

board socket. Connect power, turn sprayer ON and

 

 

 

control knob 1/2 turn clockwise. If sprayer does not

 

 

 

run, replace control board.

 

 

 

 

 

 

 

Sprayer does not run at all

Check the connections. Control

1.

Turn power OFF.

 

 

 

is not receiving a motor position

 

 

 

 

 

Digital display shows E=09

2.

Disconnect m-p sensor and inspect for damage.

sensor signal

 

 

 

3.

Reconnect sensor.

 

 

 

 

4.

Turn power ON. If error continues, replace board.