Repair / Réparation / Reparación

Motor Will Not Run

(See following page for steps)

Remove control box cover. Turn sprayer ON. Observe green light on control board.

No light

 

 

 

Once

Normal operation

 

 

Light on

Control board

Continuously

commanding

 

motor to run

 

 

Flashing

See Error Code

 

section for further

 

troubleshooting

 

 

See Step 1. Do you have over 100 AC volts?

YES

See Step 2. Do

NO

 

you have over

 

100 AC volts?

YES

Replace the

ON/OFF switch.

Repair or

NO replace power cord.

See Step 3. Is the

proper reading present through the thermal switch wires?.

YES

See step 4. Does the motor run?

YES

Replace

potentiometer.

Pressure switch.

If motor is hot, let cool and retest. If Step 4 still shows

NO incorrect resistance, replace motor. The motor has

a defective thermal device.

 

 

 

Connect a test

 

NO

 

 

transducer to the

 

 

 

board. Does the

 

 

 

 

 

 

 

 

 

 

 

motor run?

 

 

 

 

 

 

NO

YES

Replace the

 

 

control board.

 

 

 

 

 

 

Replace the

transducer

40

313314B

Page 40
Image 40