Repair / Réparation / Reparación

 

 

 

 

 

WHAT TO CHECK

 

WHAT TO DO

TYPE OF PROBLEM

If check is OK, go to next check

 

When check is not OK, refer to this column

 

 

 

 

 

 

 

 

Sprayer does not run at all

Check to see if control board power

1.

Make sure motor air intake is not blocked.

 

module is operating at a high

 

 

Digital display shows E=10

2.

Make sure control board is properly connected

temperature. Module is likely too hot

 

 

or motor is running too hot.

 

to back plate and that conductive thermal paste

 

 

 

is used on power components.

 

 

3.

Replace control board.

 

 

 

 

Control board status light blinks

 

4.

Replace motor.

10 times repeatedly

 

 

 

 

 

 

 

 

Electric Motor Will Not Shut Off

1.Relieve Pressure, page 15. Leave prime valve open and power switch OFF.

Troubleshooting Procedure

Plumb pressure gauge into paint hose, plug sprayer in, and turn power switch ON. Does sprayer reach or exceed its maximum pressure?

2.Remove control box cover so the control board status light can be viewed if available.

NO

 

 

Mechanical problem: See the proper

 

 

fluid pump manual for the sprayer for

 

 

 

 

 

 

 

further trouble shooting procedures.

 

 

 

 

YES

Unplug the transducer from control board. Does motor stop running?

NO

Replace the control board.

YES

Bad transducer. Replace and test

with a new one.