Repair / Réparation / Reparación

Electrical Troubleshooting

 

WHAT TO CHECK

WHAT TO DO

TYPE OF PROBLEM

If check is OK, go to next check

When check is not OK, refer to this column

 

 

 

 

 

 

Sprayer does not run at all

See flow chart, page 40.

 

 

 

 

Digital display is blank

 

 

 

 

 

Control board status light never

 

 

lights

 

 

 

 

 

Sprayer does not run at all

See flow chart, page 40.

 

 

 

 

Digital display shows dashes

 

 

and psi icon is not blinking

 

 

 

 

 

 

 

 

Control board status light blinks

WatchDog Activated

Reset Watchdog

once when switch is turned on

 

 

 

but then stays off

 

 

 

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Make sure there is no pressure in the system (see

 

connections

 

Pressure Relief, page 15). Check fluid path for

Digital display shows E=02

 

 

 

clogs, such as clogged filter.

 

 

 

 

 

2.

Use airless paint spray hose with no metal braid

 

 

 

1/4 in. x 50 ft minimum. Smaller hose or metal braid

 

 

 

hose may result in high-pressure spikes.

 

 

 

 

Control board status light blinks

 

3.

Set sprayer to OFF and disconnect power to sprayer.

2 times repeatedly

 

 

 

 

 

 

4.

Check transducer and connections to control board.

 

 

5.

Disconnect transducer from control board socket.

 

 

 

Check that transducer and control board contacts

 

 

 

are clean and secure.

 

 

6.

Reconnect transducer to control board socket.

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

1/2 turn clockwise. If sprayer does not run properly,

 

 

 

set sprayer to OFF and go to next step.

 

 

7.

Install new transducer. Connect power, set sprayer

 

 

 

ON and control knob 1/2 turn clockwise. Replace

 

 

 

control board if sprayer does not run properly.

 

 

 

 

34

313314B

Page 34
Image 34
Graco Inc 313314B, 300E important safety instructions Electrical Troubleshooting, If check is OK, go to next check