g0651/g0652 10" extreme series table saws -29-
11. Model G0652 only: verify that the power is
connected in phase by starting/stopping the
table saw and determining if the motor turns
in the correct direction, using the criteria
below:
if the blade turns clockwise (toward the
front of the saw), it is turning in the correct
direction.
if the blade turns counterclockwise, (toward
the back of the saw), it is turning in the
wrong direction.
stop the table saw, shut OFF the power
source, swap any two of the three power
wires—l1, l2, or l3—that connect to the
saw. if using a phase converter for 220v
3-phase operation, only swap l1 and l2,
as shown in figure 33.
incoming
power Wires
figure 33. example of switching incoming power
wires l1 and l2.
CD&(
A'( A(*A&&
6
C8&*
=di
=di
=di
H9:
B6"&-
Contactor
12. the saw is now ready to operate.