-14- g0651/g0652 10" extreme series table saws

full Load Amp Draw

g0652 220v 3-phase ..............................14 amp
g0652 440v 3-phase ................................7 amp

power Supply circuit Requirements

you must connect your machine to a grounded
circuit that is rated for the amperage given below.
never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualied electrician to ensure compliance
with wiring codes. If you are unsure about the
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult
a qualified electrician.
minimum Circuit size (220v) .................20 amps
minimum Circuit size (440v) .................15 amps
Model G0652 220/440v Operation
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the setup pro-
cess. DO NOT connect the machine to the
power source until instructed after setup.
Electrocution or fire could
result if t his machine is
not installed to code. you
MuST ensure compliance
by checking with a quali-
fied electrician!
<gdjcY^c\E^c
8jggZci
8Vggn^c\
7aVYZh
<gdjcYZY
DjiaZi7dm
figure 3. recommended connection types.
8dcYj^i
id
BVX]^cZ
8dcYj^i
id
EdlZgHdjgXZ
15-20
plug & outlet
for 220v, 3-phase
hardwired locking
disconnect switch
for 440v, 3-phase

phase converter precaution

the power from the manufactured leg may dam-
age electrical components if connected to the
wrong incoming power terminal on your machine.
only connect the manufactured leg to the l3 ter-
minal (see page 62 for identification).
NOTICE
The Model G0652 is prewired for 220v
operation. If you plan to use your machine
at 440v, you MuST have a qualified electri-
can perform the 440v conversion described
on page 15.

Minimum cord Requirements

For 220v connection, use a stranded-copper ex-
ible cord that meets the minimum requirements
listed below, does not exceed 50 ft., and has an
insulation type that starts with "s." a qualied
electrician must determine the best cord to use
in your environment depending on exposure to
moisture, heat, and oils.
For 440v connection, an electrician must
hardwire the machine. the electrician who hard-
wires the machine will determine the appropriate
wire to use inside the conduit.
g0652 220v 3-phase ....15-20/12 aWg, 300vaC
g0652 440v 3-phase ......electrician to hardwire

power connection Device

the power connection device depends on the
type of installed or planned ser vice. We recom-
mend using one of the d evices shown in figure
3, depending on the voltage being used.