Model G0652

220/440V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the setup pro- cess. DO NOT connect the machine to the power source until instructed after setup.

Electrocution or fire could result if this machine is not installed to code. You MUST ensure compliance by checking with a quali- fied electrician!

Minimum Cord Requirements

For 220V connection, use a stranded-copper flex- ible cord that meets the minimum requirements listed below, does not exceed 50 ft., and has an insulation type that starts with "S." A qualified electrician MUST determine the best cord to use in your environment depending on exposure to moisture, heat, and oils.

For 440V connection, an electrician MUST hardwire the machine. The electrician who hard- wires the machine will determine the appropriate wire to use inside the conduit.

G0652 220V 3-Phase....

15-20/12 AWG, 300VAC

G0652 440V 3-Phase

Electrician to Hardwire

Power Connection Device

The power connection device depends on the type of installed or planned service. We recom- mend using one of the devices shown in Figure 3, depending on the voltage being used.

NOTICE

The Model G0652 is prewired for 220V operation. If you plan to use your machine at 440V, you MUST have a qualified electri- can perform the 440V conversion described on Page 15.

Full Load Amp Draw

<gdjcYZY DjiaZi7dm

8jggZci 8Vggn^c\ 7aVYZh

<gdjcY^c\E^c

15-20

Plug & Outlet

for 220V, 3-Phase

G0652 220V 3-Phase

14

Amp

G0652 440V 3-Phase

7

Amp

Power Supply Circuit Requirements

You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing cir- cuit with one of higher amperage without consult- ing a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to con- nect your machine to a shared circuit, consult a qualified electrician.

Minimum Circuit Size (220V)

20 Amps

Minimum Circuit Size (440V)

15 Amps

-14-

Hardwired Locking

Disconnect Switch

for 440V, 3-Phase

8dcYj^i

8dcYj^i

id

id

BVX]^cZ

EdlZgHdjgXZ

 

Figure 3. Recommended connection types.

Phase Converter Precaution

The power from the manufactured leg may dam- age electrical components if connected to the wrong incoming power terminal on your machine. Only connect the manufactured leg to the L3 ter- minal (see Page 62 for identification).

G0651/G0652 10" Extreme Series Table Saws

Page 16
Image 16
Grizzly G0651 Model G0652 220/440V Operation, Minimum Cord Requirements, Full Load Amp Draw, Phase Converter Precaution