440V Conversion

The Model G0652 can be converted for 440V operation. This conversion job consists of discon- necting the saw from the power source, rewiring the motor, switching the transformer fuse from 220V to 440V, and changing the thermal overload relay from 14 to 7 Amps. Refer to the photos and wiring diagram on Pages 61 and 63 for wiring details.

All wiring changes must be inspected by a quali- fied electrician before the saw is connected to the power source. If, at any time during this procedure you need help, call Grizzly Tech Support at (570) 546-9663

G0651/G0652 10" Extreme Series Table Saws

-15-

Page 17
Image 17
Grizzly G0652, G0651 owner manual 440V Conversion