g0651/g0652 10" extreme series table saws -27-
fence components
To install the fence knobs, fence, and fence
resting brackets:
1. install the fence knob as shown in figure
30.
figure 30. Fence knob installed.
2. install the fence onto the table to the right of
the blade.
3. Check for fence parallelism and adjust if
needed. see Adjusting fence on page 56.
4. install the fence resting brackets (figure
31) onto the back of the cabinet with the two
m8-1.25 x 12 hex bolts and flat washers.
figure 31. Fence resting brackets installed.
Brackets
x 2
Dust collection
DO NOT oper ate the Model G0651/G0652
without an adequate dust collection system.
This saw creates substantial amounts of
wood dust while operating. failure to use a
dust collection system can result in short
and long-term respiratory illness.
Recommended cfM at Dust port: 400 cfM
Do not confuse this CFM recommendation with
the rating of the dust collector. To determine
the CFM at the dust port, you must consider
these variables: (1) CFM rating of the dust col-
lector, (2) hose type and length between the
dust collector and the machine, (3) number
of branches or wyes, and (4) amount of other
open lines throughout the system. Explaining
how to calculate these variables is beyond the
scope of this manual. Consult an expert or pur-
chase a good dust collection "how-to" book.
To connect a dust collection hose:
1. Fit the 4" dust hose over the dust port, as
shown in figure 32, and secure in place with
a hose clamp.
2. tug the hose to make sure it does not come
off. Note: A tight fit is necessary for proper
performance.
figure 32. dust hose attached to dust port.
components and hardware Needed: Qty
4" dust hose (not included) ...............................1
4" hose Clamp (not included) ............................2
dust Collection system (not included) ...............1