Example #4: What are the Imager’s settings for all Codabar selections?

Enter: cbr?.

Response: CBRENA1[ACK],

CHK0[ACK],

CKX0[ACK],

SSX0[ACK],

MIN2[ACK],

MAX60[ACK],

DFT[ACK].

This response indicates that the Imager’s Codabar Coding Enable (CBRENA) is set to 1, or on;

the Check Character (CHK and CKX) is set to 0, or No Check Character; the Start/Stop Character is set to 0, or Don’t Transmit;

the Minimum Message Length (MIN) is 2 characters; the Maximum Message Length (MAX) is 60 characters; and the Default setting (DFT) has no value.

Trigger Commands

You can activate and deactivate the scanner with the serial trigger commands. First, the scanner must be programmed for accepting serial commands by scanning the Serial Triggering On bar code on page 2-14, or by sending the serial command (TRGSER1.) on page 7-15. When the serial trigger factory default settings are used and serial triggering is enabled, the trigger is activated and deactivated by sending the following commands:

Activate

SYN T CR

Deactivate

SYN U CR

The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial timeout has been reached. See "Trigger Timeout" on page 2-15 for a description and the serial command on page 7-15.

7 - 12

IMAGETEAM™ 4410/4710 User’s Guide

Page 142
Image 142
Hand Held Products 4410, 4710 manual Trigger Commands, Enter cbr? Response CBRENA1ACK