Linear Symbologies

Code 93

< Default All Code 93 Settings >

Code 93

On

* Off

Message Length

The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will not read the symbol. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread.

EXAMPLE: Decode only those bar codes with a count of 9-20 characters.

Min. length = 09 Max. length = 20

EXAMPLE: Decode only those bar codes with a count of 15 characters.

Min. length = 15

Max. length = 15

Minimum

Maximum

Message Length

Message Length

The desired message length and Save must be input after reading this programming symbol. Refer to the Programming Chart (inside back cover).

3 - 14

IMAGETEAM™ 4410/4710 User’s Guide

Page 84
Image 84
Hand Held Products 4410, 4710 manual Default All Code 93 Settings