7 - 28 IT5600/IT5800 User’s Guide

MSI, continued

MSI Check Character

Different types of check characters are used with MSI bar codes. You can
program the scanner to read MSI bar codes with Type 10 check characters.
Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to
Validate and Transmit
, the scanner will only
read MSI bar codes printed with the specified type check character, and will
transmit this character at the end of the scanned data.
When Check Character is set to
Validate, but Don’t Transmit
, the unit will only
read MSI bar codes printed with the specified type check character, but will not
transmit the check character with the scanned data.

MSI Message Length

Scan the bar codes below to change the message length. Refer to Message
Lengthon page 7-2 for additional info rmation. Minimum and Maximum
lengths = 4-48. Minimum Default = 4, Maximum Default = 48.
Validate Type 10 and Transmit
* Validate Type 10, but Don’t
Transmit
Minimum Message Length
Maximum Message Length